Den externa diskettenhetsportens pinkonfiguration
Pinkonfiguration för Amigans externa diskettenhetsport.
| Namn | I/O | Beskrivning |
1 | /RDY | I/O | Disk Ready |
2 | /DKRD | I | Disk Read Data |
3 | GND | - | Jord |
4 | GND | - | Jord |
5 | GND | - | Jord |
6 | GND | - | Jord |
7 | GND | - | Jord |
8 | /MTRXD | OC* | Disk Motor Control |
9 | /SEL2 | OC* | Select Drive 2 |
10 | /DRES | OC* | Disk Reset |
11 | /CHNG | I/O | Disk Removed From Drive--Latched Low |
12 | +5V | - | +5 Volts DC (250 mA maximum) |
13 | /SIDE | O | Select Disk Side--0=Upper, 1=Lower |
14 | /WPRO | I/O | Disk Is Write Protected |
15 | /TK0 | I/O | Drive Head Position Over Track 0 |
16 | /DKWE | OC* | Disk Write Enable |
17 | /DKWD | OC* | Disk Write Data |
18 | /STEP | OC* | Step The Head--Pulse, First High, Then Low |
19 | DIR | OC* | Select Head Direction--0=Inner, 1=Outer |
20 | /SEL3 | OC* | Select Drive 3 |
21 | /SEL1 | OC* | Select Drive 1 |
22 | /INDEX | I/O | Disk Index Pulse |
23 | +12V | - | +12 Volts DC (160 mA maximum) |
* OC = Open Collector
Några av stiften i porten är avsedda för
strömförsörjning av mindre, externa enheter. Anslut
endast dessa stift om det krävs för den externa
utrustningen. Man bör alltid försöka ta
strömmen direkt från nätagget om det är
möjligt. Ett snedstreck framför signalnamnet (t.ex.
/RDY) anger att signalen är aktiv låg.